P30UDP commands
UDP Programmers Guide V2.01
30
© KEBA
3.2.12 UDP command: display
Command structure
Command Parameters Additional Description
display [a]
[min] [max]
[tk] [text]
[a]
Determines whether default or non-default
values are used for the duration [text] is dis-
played. 0 = default (min duration = 2 sec,
max duration = 10 sec, fixed token); 1 = min
and max duration can be defined.
[min]
Defines the duration in seconds how long the
text is displayed before another display com-
mand will be processed (internal MID meter-
ing relevant information may overrule this).
[max]
Defines the duration in seconds how long the
text is displayed if no additional display com-
mand follows.
[tk] Token – for internal use only.
[text]
Text shown on the display. A maximum of 23
ASCII characters can be used.
Note: $ will be replaced by a blank space. ~
will be replaced by a Σ
Reply structure
Field Contents Additional Description
- TCH-OK: done Generic confirmation message
Example
3.2.13 UDP command: unlock
The command unlock unlocks the socket of the device. The charging
process has to be stopped first (e.g. via currtime 0 1 or ena 0)
Command structure
Command Parameters Additional Description
unlock
- -