P30 UDP commands
UDP Programmers Guide V2.01
33
© KEBA
booted. The only option to remove a curr setting without a restart is to over-
write it with a currtime command. When the currtime setting is copied
from "Curr timer" to "Curr user" the value from a previous curr is overwritten
and thus is resettable by unplugging (see section command: currtime). In
general, it is not recommended to use the curr command, since the current
can be easily controlled via the non-permanent currtime. If the charging
current of the charging station needs to be lowered permanently, a reconfig-
uration of the DIP switch settings is recommended (see “installation man-
ual”).
Command structure
Command Parameters Additional Description
curr [c]
[c]: Current setting
Current value in mA
Possible values: 6000 - 63000
Reply structure
Field Contents Additional Description
- TCH-OK: done Generic confirmation message
Example
● Vehicle is charging.