10.3.4 Shielding inside the Control Cabinet
In many cases, several interference sources exist in the control cabinet,
such as servo drive modules, transformers, contactors and relays.
Therefore it is necessary to continue the cable shield from the connector
shell (control cabinet) up to the PLC (continuous connection from handheld
terminal up to PLC).