10.4.8 Technical Data of Connection Box KeTop CB211
General data
Rated supply voltage:
24 V DC (voltage tolerance 19.2 V DC to 30 V DC
according to EN 61131-2))
Maximum interruption time of supply volt-
age:
≤ 10 ms (lt. IEC 31131)
Power consumption:
with KeTop: 3.6 W (150 mA at 24 V DC)
without KeTop: 10.8 W (450 mA at 24 VDC)
Inrush current: max. 5.6 A (by implemented inrush current limiter)
Protective class: Class III equipment (in accordance with EN
61131-2 and EN 50178)
Environmental conditions
Operating temperature: 0 °C to 50 °C (32 °F to 122 °F)
Storage temperature: -20 °C to +70 °C (-4 °F to 158 °F)
Relative humidity (non-condensing): 5 % to 95 %
Vibration resistance (operation): (IEC 60068-2-6)
5 < f < 9 Hz 7 mm
9 <
f < 150 Hz 2g (0.0044 pound)
Shock resistance (operation): 15 g (0.033 pound) / 11 ms (IEC 60068-2-27)
Housing
Construction
Double-walled ABS housing
Withstands grease, oil, lubricants,
alcohol, etc.
Flammability class: UL94-V0
Dimensions:
Width: 160 mm
Height: 140 mm
Depth: 70 mm
Protection degree: IP65
Weight: 500 g (1.1 pound)
Display: Status LEDs
Accessories
Intermediate cable Connection box to connection cable
KeTop IC220: 2 m / 6.56 ft
KeTop IC240: 4 m / 13.12 ft
Download cable
KeTop XD040: 4 m / 13.12 ft. For downloading software and for
debugging via S2.
DIN Rail Holder Mounting Set
KeTop DR200: For mounting on the rearside of a KeTop CB2xx
gatewaybox.