Handheld Terminal KeTop - Specific Operating Instructions
User's Manual, Version: 1.3 95
© KEBA 2007
trols the function. After calibration, the number specifies the current value of
the joystick (value range: -15 .. 15 for each joystick axis).
This value is also the value the KeTop API function KtpGetJoystickPos
supplies to the application.
8.2.2 Calibration of Potentiometer
A number is displayed next to the slide bar. During calibration, this number
specifies the current value of the ADC (value range: 0..1024) and only con-
trols the function. After calibration, the number specifies the current value of
the potentiometer (value range: 0 ...127).
This value is also the value the KeTop API function KtpGetOverridePoti
supplies to the application.
8.2.3 Display and Touch Screen Settings
In this window, the brightness for the display can be set.
In this window you can also calibrate the touch screen.