Issue departmentBedding Division Date
2017-05-03
ProductFunction
instruction
Author
Kyle
MC120PR
Version: 1.1
Page 2 of 3
2
1.4. Power LED& PAIRING LED
Powersupplyforcontrolbox,PAIRINGLEDofcontrolboxflashesfor4times,andthenturnsoff,POWERLEDturns
on
1.5. Power
Connecttothe29VDC;
1.6. Test for underbed light
Clickbuttonofunderbedlight,turnson(orturnsoff)theunderbedlight,switchthestatusoncewhenclick once
Thisfunctiontakeseffectonlybypressingthecorrespondingbuttonontheremote.
1.7. FLAT function
PressandreleasetheFLAT buttonon remotetheheadandfoot actuatorsmovestolowerposition(whenthe
actuatorisfree,canturnoffthevibrationmotorandturnofftheindicatorlightwhenpressonce)stopwhen
pressanybuton
Thisfunctiontakeseffectonlybypressingthecorrespondingbuttonontheremote.
1.2. FOOT port
Connecttofootactuator,controlbyremotesingle:
Clickfoot up buttonfootactuatormovesoutstopwhenreleased
Clickfoot downbuttonfootactuatormovesinstopwhenreleased
Thisfunctiontakeseffectonlybypressingthecorrespondingbuttonontheremote.
1.3. MULTIFUNCTION port