Kelly KLS-M/N Brushless Motor Controller Users Manual V 2.5
17
Turn the PWR switch on.
The fault code will be detected automatically at restart.
With the brake switch open, select a direction and operate the throttle. The motor should
spin in the selected direction. Verify wiring or voltage and the fuse if it does not. The motor
should run faster with increasing throttle. If not, refer to the Table 1 code, and correct the
fault as determined by the fault code.
Take the vehicle off the blocks and drive it in a clear area. It should have smooth
acceleration and good power.
Chapter 4 Programmable Parameters
KLS Configuration program allow users to set parameters according to the vehicle actual
working environment so as to be at its best.
The default parameters of the controller are not recommended for all applications. Make
sure set the proper parameters before making any test to avoid danger.
Customers can do program on PC software or Android App.The Android Tablet is
prefered.First of all,people need to do Identification angle function for KLS controller before
running the motor.The controller needs to be connected to batteries,motor and throttle before
Identification operation.That is to say,it is not enough to connect only power supply(PWR=pin7)
to batteries for Identification Angle operation.
Please download the instruction how to use Identification angle function from our website.
www.kellycontroller.com/support.php
4.1 Step 1
(1)Low Volt: The min voltage of reporting this fault - Range 18~105
Controller will not operate when battery voltage is near the value so as to protect battery.
Suggestion: Set according to the practical situation.By default,it is set at 18V.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kelly KLS Series and is the answer not in the manual?

Kelly KLS Series Specifications

General IconGeneral
Motor TypeBLDC, PMSM
DimensionsVaries by model
WeightVaries by model
Voltage Range24V-72V
Storage Temperature Range-40°C to 85°C
CommunicationCAN
Protection FeaturesOver-voltage, Under-voltage, Over-current, Over-temperature, Short-circuit