4 Minimum floor areas / components
Minimum floor areas
Your air conditioner is designed to condition the air for a certain
range of room sizes, please ensure the selection of your air
conditioner complies with the Kelvinator selection tool available
from www.kelvinator.com.au
This product uses refrigerant R32. Certain levels of refrigerant
require minimum room sizes. Please ensure that these minimum
room sizes are adhered to for standard installations (7.5m pipe
length). If larger refrigerant charges than standard are used then
please consult AS60335.2.40 to determine the safe minimum floor
area for the installation.
Model no. Charge of R32 (g) Minimum floor area (m
2
)
KSV25CRF 710 n/a*
KSV25HRF 710 n/a*
KSV35CRF 970 n/a*
KSV35HRF 970 n/a*
KSV52HRF 900 n/a*
KSV70CRF 1300 1.87
KSV70HRF 1400 1.87
KSV80HRF 1700 2.76
*no minimum floor area required for this product
Items required for installation
• Level gauge
• Screw driver
• Electric drill
• Hole core drill ( 55mm / 70mm)
• Flaring tool specifically designed for R32 or
R410a refrigerant
• Specified torque wrenches
• Spanner (half union)
• A glass of water
• Hexagonal wrench (6mm)
• Gas-leak detector
• 2 stage vacuum pump
• Gauge manifold
• Users manual
• Thermometer
• Multimeter
• Pipe cutter
• Measuring tape
Number Description Quantity
1 Indoor unit mounting plate 1
2 Clip anchor not supplied
3
Self-tapping screw ST4 x 25
- for KSV70CRF, KSV70HRF & KSV80HRF
10
- for all other models 5
4 Remote control 1
5 Remote control holder 1
6 Screw for remote holder 2
7 Battery (AAA 1.5V) 2
8 Insulation material not supplied
9
Connection piping assembly
(refer to page 8)
varies by
country
10 Insulation hose for refrigerant piping not supplied
11 Wall clamp not supplied
12 Drain hose not supplied
13 Connection power cable not supplied
14
Drain connector
(heat pump model only)
1
15
Drain plug (reverse cycle models with
capacity of over 4500W)
3
16
Thermal insulating pipe for extending
drain hose
1
17 Flare nut 2
NOTE: Other parts necessary for installation besides those
mentioned above must be supplied by the customer/installer.
Components