Kemper FROSTI - Drinking Water Installation; Installation Requirements for Drinking Water

Kemper FROSTI
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 / 12 K410057700003-00 / 09.2018 – © www.kemper-olpe.de
BS EN 1717
BS EN 806
max.
min. 250**
min. 100**
DN
Drinking water installation
In order to prevent stagnation and bacterial contamination
in the supply, it is recommended to loop the tap in
the drinking water system.
* For technical and hygienic reasons, it is necessary to
install the last min. 100 mm and max. 10 x DN as a
functional individual supply line.
** The tap must be installed at least 250 mm above
the maximum fluid level.
Warning! The FROSTI must be installed in accord-
ance to Water Regulations, schedule 2, paragraph
15. The level of protection must be appropriate to
the fluid category.