Fault finding on the high pressure cleaners
Motor protection has been
released.
Turn the red stop knob until it jumps
out.
Insufficient water supply.
See section: Before start.
Retighten / replace gaskets.
Pump valves dirty or worn.
(pulsate)
Clean / replace, see spare parts
drawing.
Flow valve dirty or worn.
Take apart and clean valve, replace
defective parts. X) see spare parts
drawing.
Check flow through hose, gun and nozzle pipes.
Injector cannot suck chemicals
Non-return valve gone slack sucks
dead air.
Retighten, replaces nylon gasket.
Ball hangs (old soap residue)
Dismount chemicals hose - loosen
ball from top with match or similar
object.
Low pressure nozzle on double
nozzle pipe choked
Flow valve shuts off during
operation (pressure increase)
Valve or double nozzle pipe
pinched or dirty.
Spring in flow valve gone slack.
Motor protection switches off
Check plug / fuse / cable
Defect motor / pump. – Dismount V-belt or pump (inlet and outlet hoses
must be disconnected). Pump movement must be even and free of
metallic sounds. If abnormally heavy when turning: Call your dealer’s
service department. Electric motor must run smoothly, without noise.
*) Let your dealer makes repairs and adjustments.