Do you have a question about the KEPO AC 15 and is the answer not in the manual?
Category | Stove |
---|---|
Power | 1500W |
Voltage | 220-240V |
Frequency | 50/60Hz |
Number of Heating Zones | 1 |
Material | Ceramic |
Safety Features | Overheat Protection |
Guidance on correctly installing the boiler and its accessories as per manual regulations and manufacturer notes.
Specifies minimum clearances for boiler sides, back, front, and room height for service access.
Details required air vents for fresh air intake and dirty air exhaust for proper boiler operation.
Defines regulations for flue pipe diameter, length, horizontal mounting, and chimney insulation.
Mandates chimney cleaning before commissioning and prohibits connecting other devices to the same chimney.
Ensures stable power supply (230V ± 5%) and correct boiler positioning with non-combustible clearances.
Details chimney conditions, clearance to combustibles, uniform pipe structure, and insulation requirements.
Allows setting the current time, date, month, and year for the boiler's operation.
Enables setting automatic operation schedules for the boiler based on daily, weekly, or weekend programs.
Option to choose the display language for the boiler's control unit.
Setting the operating season (Winter/Summer) to optimize boiler performance.
Configures the boiler's standby mode for automatic on/off cycles based on temperature.
Enables or disables audible alarms for malfunctions or events.
Initiates the pellet feeder to fill the fire pot, used during first commissioning or after pellet tank refill.
Displays current operational status, temperatures, speeds, and stage of the boiler.
Access to technical parameters for advanced boiler settings, typically for technicians.
Instructions for cleaning the heat exchangers using a lever, recommended every 3 days.
Guidance on cleaning the fire pot and its casing for MC series boilers, advised every 15 days.
Details on automatic cleaning of the fire pot for AC series boilers and manual cleaning for deposits.
Procedure for emptying the ash pan, recommended every 5-10 days depending on pellet usage.
Instructions for cleaning the back chamber of the boiler after significant pellet usage (500-1000kg).
Method for cleaning the brass opening for the pressure switch after 2000kg of pellet usage.
Major cleaning of heat exchangers performed annually as part of service, initially by a technician.
Flue pipes cleaning as part of annual service, or more often if needed based on pellet quality.
Annual cleaning of the ventilator as part of the regular maintenance service.
Annual control of all electro-mechanical components as part of the service.
Illustrates the hydraulic connections for a standard boiler setup with a mixing valve and room thermostat.
Shows hydraulic connections for a boiler system incorporating a heat accumulator, secondary pump, and expansion tank.