PLANETARYGEARREDUCERS
#6 17ozs.
#8 42ozs.
#9 42ozs.
B. Ifpumphaslubricatingfacilitiesforstuffingboxes,checkleveloflubricant.
C. Maintainpackingglandtensiononpacking(Donotover‐tighten)
D. Visuallyinspectpumpforapparenttrouble.
E. Keepthepumpclean.
GENERAL
Replaceanyworkpartbeforeitseventualfailure.Usethefollowinginstructionsforremovalandreplacementofparts.Don’thesitatetocall
onKerrPumpsforhelpifnecessary.
SERVICEPROCEDURES (ALLMODELS)
A. WINGGUIDEDVALVES
i. DISCHARGEVALVES:Thedischargevalveandseatcanbeexposedbyfirstremovingthedischargevalvecovercap.Oncethe
dischargecovercaphasbeenremovedyoumayliftoutthedischargevalvespringandthedischargevalve.Thevalveseatwillbeheld
inplacebyataperfitandmustbe“pulled”withanappropriatevalve‐pullingtool(availablefromtheKerrPumpsDealers).Oncethe
valveandseathavebeenremovedtheyshouldberesurfacedorreplacedifbadlyworn.Toreplacethedischargevalve,firstcleanand
inspecttheseatboreforwashoutdefectsandthendroptheseatintothebore.Replacethevalveintotheseatandstrikethetopof