45
EN
ALT324KF PARAMETERS
PARAMETERS DESCRIPTION DEFAULT MIN MAX UNIT
1
TCL
Automatic reclosure time (0 = o󰀨) 0 0 900 s
2
ttr
Reclosing time after transit on PH1
(0 = o󰀨)
0 0 30 s
3
SEI
Sensitivity on obstacles
0 = Maximum impact force
10 = Minimum impact force
3 0 10
4
SFO
Motor speed during opening
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
4 1 5
5
SFC
Motor speed during closing
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
4 1 5
6
SBS
STEP BY STEP or SBS conguration:
0 = Normal (AP-ST-CH-ST-AP-ST…)
1 = Alternate STOP (AP-ST-CH-AP-ST-CH…)
2 = Alternate (AP-CH-AP-CH…)
3 = Apartment block – timer
4 = Apartment block with immediate reclosure
4 0 4
7
LSI
Deceleration distance in opening
from 40 to 100 = Motor deceleration percentage
during opening
55 40 100 %
8
LS2
Deceleration distance in closing
from 40 to 100 = Motor deceleration percentage
during closure
68 40 100 %
9
BlT
Post blackout procedure
0 = No action, remains stationery
1 = Closure
0 0 1 s
10
SBY
Energy saving: enables photocell switch-o󰀨 when
barrier is closed
0= disabled
1= enabled
0 0 1

Related product manuals