Loading...
Introduction 1
Keysight N8900 Rack System Installation Guide 9
Characteristics
Number of Units in Parallel
N8932A/N8952A
2
3
4
5
6
Output ripple & noise
CV peak-to-peak:
740/600 mV
Load Effect
Voltage:
Current:
100 mV
0.063 A
100 mV
0.945 A
100 mV
1.26 A
100 mV
1.58 A
100 mV
1.89 A
Current programming &
measurement accuracy:
≤ 0.840 A
≤ 1.26 A
≤ 1.68 A
≤ 2.1 A
≤ 2.52 A
Voltage programming &
measurement accuracy:
≤ 200 mV
Transient response
Recovery Time:
Settling band:
≤ 3 ms
2.0 V
Output response time
Up, full load:
Down, full load:
Down, no load:
≤ 30 ms
≤ 80 ms
≤ 10 s
Characteristics
Number of Units in Parallel
N8934A/N8954A
2
3
4
5
6
Output ripple & noise
CV peak-to-peak:
700 mV
Load Effect
Voltage:
Current:
250 mV
270 mA
250 mV
405 mA
250 mV
540 mA
250 mV
675 mA
250 mV
810 mA
Current programming &
measurement accuracy:
≤ 0.36 A
≤ 0.54 A
≤ 0.72 A
≤ 0.90 A
≤ 1.08 A
Voltage programming &
measurement accuracy:
≤ 500 mV
Transient response
Recovery Time:
Settling band:
≤ 3 ms
5.0 V
Output response time
Up, full load:
Down, full load:
Down, no load:
≤ 30 ms
≤ 80 ms
≤ 10 s