EasyManua.ls Logo

Keysight 33210A - Page 206

Keysight 33210A
351 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
204
Chapter 4 Remote Interface Reference
Frequency Sweep Commands
4
4 Set the sweep time.
Use the SWE:TIME command to set the number of seconds required to
sweep from the start frequency to the stop frequency.
5 Select the sweep trigger source.
Use the TRIG:SOUR command to select the source from which the sweep
will be triggered.
6 Set the marker frequency. (Optional)
If desired, you can set the frequency at which the signal on the front-panel
Sync connector goes to a logic low during the sweep. Use the MARK:FREQ
command to set the marker frequency to any value between the start
frequency and stop frequency. Use the MARK ON command to enable the
frequency marker.
7 Enable the sweep mode.
After you have set up the other sweep parameters, use the SWE:STAT ON
command to enable the sweep mode.
33210A users guide.book Page 204 Wednesday, July 16, 2008 11:16 AM