281
Chapter 5 Error Messages
Execution Errors
4
5
-221 Settings conflict;
not able to burst noise, burst turned off
The function generator cannot generate a burst using the noise function.
The burst mode has been turned off.
-221 Settings conflict;
not able to sweep noise, sweep turned off
The function generator cannot generate a sweep using the noise function.
The sweep mode has been turned off.
-221 Settings conflict;
not able to sweep arb waveforms, sweep turned off
The function generator cannot generate a sweep using the arbitrary
waveform function. The sweep mode has been turned off.
-221 Settings conflict;
pulse width decreased due to period
For a pulse waveform, the function generator will automatically adjust
the waveform parameters in the following order as needed to generate
a valid pulse: (1) edge time, (2) pulse width or duty cycle, and then (3)
period.
In this
case, the function generator has decreased the pulse width to
accommodate
the specified period (the edge time is already at its
minimum setting).
-221 Settings conflict;
pulse duty cycle decreased due to period
For a pulse waveform, the function generator will automatically adjust
the waveform parameters in the following order as needed to generate
a valid pulse: (1) edge time, (2) pulse width or duty cycle, and then (3)
period.
In this
case, the function generator has decreased the pulse duty cycle to
accommodate
the specified period (the edge time is already at its
minimum setting).
33210A users guide.book Page 281 Wednesday, July 16, 2008 11:16 AM