QUEStionab[e:lNSTrument:lSUMmary<n> subregister
Bit <n>
subregister of the
QUEStionable:INSTrument
subregister.
For example, channel
2
(lNSTrument2) is
QUEStionable:INSTru-
ment:ISUMmary2.
The <n>
values that
can
be used for the PLZ-U are
1 to 5.
Table
6-8 QUEStionable:INSTrument:lSUMmary
status register
(STATus:QUEStionable:iNSTrument:ISUMmary)
Bit Bit Weight
Bit Name
Description
0 1
OV
Over Voltage
I 2
oc
Over Current
2 4
Not
Used
3 8
OP
Over Power
4
16
err Over Temper^re
5 32
Not Used
6 64
Not Used
7
128 Not Used
8
256 Not
Used
9 512 UV
Under Voltage
10
1024 EXT
Eternal Problem
11
2048 REV
Reverse Voltage
12
4096 Not
Used
13
8192
Not Used
14 16384
Not Used
15
32768 Not Used
Always 2ero
STAT:QUES:INST:ISUM
Queries the
event of the
QUEStionable;INSTrument:lSUMmary
subregister.
Query
command: STATus
:
QUEStionable
: INSTrument
:
ISUMmary<n> [ : EVENt ]
?
STAT:QUES:INST:ISUM:COND
Queries the
condition of the
QUEStionable:INSTniment:ISUMmary
subregister.
Query command:
STATus
:
QUEStionable :
INSTrument
:
ISUMmary<n> :
CONDition?
STAT:QUES:1NST:ISUM:ENAB
Sets
the
QUEStionable:INSTrument;ISUMmary
subregister
enable, or queries the
current setting.
Set command:
STATus
:
QUEStionable :
INSTrument
:
ISUMmary<n> :
ENABle
<status-enable>?
Query
command: STATus
:
QUEStionable :
INSTrument
:
ISUMmary<n> : ENABle?
PLZ-U
Remote
Control
6-43

Other manuals for Kikusui PLZ-U Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kikusui PLZ-U Series and is the answer not in the manual?

Kikusui PLZ-U Series Specifications

General IconGeneral
BrandKikusui
ModelPLZ-U Series
CategoryControl Unit
LanguageEnglish

Related product manuals