EasyManuals Logo

Kinco FV100 Series User Manual

Kinco FV100 Series
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
Chapter 7 List of Parameters
58
Function
code
Name
Descriptions
Unit
Factory setting
Modif.
Setting
range
(It will operate at zero frequency
when input a reverse command)
A1.13
Delay time of
run
reverse/forward
0.00~360.00s
0.01s
0.00s
O
0~36000
A1.14
Switch mode of
runreverse/forwa
rd(Reserved)
0:Switch when pass 0Hz
1:Switch when pass starting
frequency
1
0
X
0~1
A1.15
Stopping speed
0.00~150.00Hz
0.01
Hz
0.10Hz
X
0~15000
A1.16
Action voltage of
braking unit
650~750V
1
720
X
650~750
A1.17
Dynamic braking
0:Disable,
1:Enable
1
0
X
0~1
A1.18
Ratio of working
time of braking
unit to drive’s
total working
time
0.0~100.0%
0.1%
80.0%
O
0~1000
A1.19
Selection of
power outage
restarting mode
0:Current finding mode
(Only valid in V/F control; Otherwise
set to 0, starting with vector tracking)
1:Vector tracking mode
2:Depend on the parameter A1.00
1
0
X
0~2
Group A2.Frequency setting
A2.00
Auxiliary
reference
frequency
selector
0:No auxiliary reference frequency
1:AI1
2:AI2
3:AI3
4:Set by DI (PULSE)terminal
5:output by PID process
1
0
O
0~5
A2.01
Main and
auxiliary
reference
frequency
calculation
0:+
1:-
2:MAX(Main reference Auxiliary
reference)
3:MIN(Main reference Auxiliary
reference)
1
0
O
0~3
A2.02
UP/DN rate
0.01~99.99Hz/s
0.01
1.00
O
1~9999
A2.03
UP/DN
regulating
control
Unit’s place of LED:
0:Save reference frequency
uponpower outage
1
000
O
0~111H

Questions and Answers: