Injection braking
waiting time at stop
DC injection braking
current at stop
0.0%~100.0% drive’s rated
current
DC injection braking
time at stop
0.0(No action)
0.01~30.00s
Restart after power
failure
Delay time for restart
after power failure
Anti-reverse
running function
0:Disabled
1:Enabled (It will operate at zero
frequency when input a reverse
command)
Delay time of run
reverse/forward
Switch mode of run
reverse/ forward
(Reserved)
0:Switch when pass 0Hz
1:Switch when pass starting
frequency
Detecting frequency
of stop
Action voltage of
braking unit
Ratio of working time
of braking unit to
drive’s total working
time
0: Current finding mode
1: Vector tracking mode
2:Depend on the parameter A1.00
Group A2:Frequency setting
Auxiliary reference
frequency selector
0: No auxiliary reference
frequency
1: AI1
2: AI2
3: Keyboard potentiometer
4: Set by DI (PULSE)terminal
5: output by PID process
Main and auxiliary
reference
frequency
calculation
0: +
1:-
2:MAX(Main reference,Auxiliary
reference)
3:MIN(Main reference, Auxiliary
reference)
Unit’s place of LED:
0: Save reference frequency
upon power outage
1: Not save reference
frequency upon power outage.