Kinco SV100 Series User Manual

Kinco SV100 Series
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #86 background imageLoading...
Page #86 background image
83
Function
code
Name
Descriptions
Unit
Factory
setting
Modif.
Setting
range
10Bus voltage0~800V
11AI1
12AI2
13Reserved
14Reserved
15Percentage of host0~4095
16~36Reserved
A6.29
Functions of
terminal AO2
Same as above.
1
0
0~36
A6.30
Gain of AO1
0.0~200.0%
0.1
100.0%
0~2000
A6.31
Zero offset
calibration of AO1
-100.0%~100.0%
0.1%
0.0
0~2000
A6.32
Gain of AO2
0.0~200.0%
0.1
100.0%
0~2000
A6.33
Zero offset
calibration of AO2
-100.0%~100.0%
0.1%
0.0
0~2000
A6.34
AI1 filter
0.01~10.00s
0.01s
0.05
1~1000
A6.35
AI2 filter
0.01~10.00s
0.01s
0.05
1~1000
A6.36
Reserved
Group A7Reserved
Group A8Fault parameters
A8.00
Protective action
of relay
Unit’s place of LED:
Action selection for
under-voltage fault indication.
0:Disable
1:Enable
Ten’s place of LED:
Action selection for auto reset
interval fault indication.
0:Disable
1:Enable
Hundred’s place of LED:
Selection for fault locked
function.
0:Disable
1:Enable
1
0000
×
0~1111H