Do you have a question about the Kingspan UniWatchman and is the answer not in the manual?
Supports level measurement via ultrasonic or 4-20mA sensors.
Option to display tank level in centimeters or percentage.
Works with both wired and wireless Watchman transmitter models.
Includes a specific mode for monitoring waste oil levels.
Allows setting an offset for WatchmanSonic transmitters.
Features an intuitive screen menu with a guided setup wizard.
Provides theft rate alarms with audible notifications.
Indicates leak alarms with audible notifications.
Features a 128x64 graphic display with a blue backlight.
Offers two configurable relay outputs for external control.
Optional RS232/RS485 interfaces available as custom builds.
Includes an 80db buzzer for audible alarms.
Features a durable keypad membrane for user input.
Explains the function of the wireless data, alarm, and power LEDs.
Describes the function of the Up, OK, and Down buttons.
Details the display of the software version upon unit startup.
Explains indicators shown on the main operational screen.
Describes the low level notification, including nozzle icon and buzzer.
Details the theft rate alarm, its display, and audible alerts.
Explains the leak alarm, including the drop icon and buzzer.
Describes the alarm for no transmitter signal within a specified period.
Covers alarms for no echo (wireless) or no connection (wired).
Indicates the display of low battery warnings from the transmitter.
Explains how to access the setup screen from the main menu.
Guides through the setup wizard for configuring sensor type and thresholds.
Configuration options for Relay1 output.
Configuration options for Relay2 output.
Enables switching the LCD backlight ON/OFF with auto-off.
Enables switching the internal buzzer ON/OFF for alarms.
How to switch the level display between centimeters and percentage.
Defines tank height for single skin tanks.
Defines tank height for bunded tanks (inner/outer).
Defines sonic height measurement.
Explains the automatic calculation of the offset value.
Details voltage, current consumption, operating temperature, and relay current.
Diagram and description of device connection terminals.
Description of LED colors (Blue, Red, Green) and their functions.
Details contact mechanism, max voltage, and max current for relays.
Specifies transmission frequency, distance, and compatible transmitters.
Details active type, sensor supply, and overcurrent protection.
Specifies voltage type and max communication distance.
Details baud rate, data bits, parity, stop bits, and cable requirement.