- 5 -
8. Remove the double acting valve cover (A). Then, install the double acting valve assembly (1) and secure it with bolts (2)
with spring washers (3).
TG2A809A TG2A810B
TG2A811A
REMARKS
• Install the socket coupler plug (5) to the socket coupler (4). Then, install
them to the double acting valve (1).
• To avoid the interference, the detent oating valve should be installed on
the top of the 2nd valve.
9. Fit the double acting cable to the bracket and tighten it loosely. Then, install the end of the cable to the double acting
valve shaft and fix it with the head pin (17), washer 3 (16) and snap pin (15).
Adjust the double acting lever and fix the cable adjusting nut (A).
TG2A812A
10. After assembly by performing the Steps 5 to 2 above in the reverse order, insert the grip (18) to the double acting
lever and fix it with the Phillips head screw (19).
TG2A813A