PARAMETER TABLE
#
description
min
max
DF-SM
UOM
1
SET POINT: temperature control of the cabinet
SL
0
°C/°F
2
SL
minimum temperature limit of SP
-18
+80
-2
°C/°F
3
SH
maximum temperature limit of SP
0
99
8
°C/°F
4
di
differential relay function
1
50
3
°C/°F
5
Cr
minimum pause time of the compressor
0
4
0
min
6
CF
In case of sensor’s malfunction (F1), the compressor operates as follows:
0 = 40% ΟΝ compressor’s operation (3min ΟΝ, 4min OFF),
1 = compressor is ΟΝ continuously.
0
1
0
-
7
dF
frequency of defrosts per 24h, where:
0 =
the deFrost is deactivated and
for ex. if put dF=6 →24h / 6 = 4h, which means every 4 hours the defrost starts
0
12
4
hours
8
dT
maximum duration of deFrost (automatic and manual)
1
90
18
min
9
dL
temperature limit of deFrost: above this temperature the automatic defrost stops.
The manual defrost does not stop according to “dL” temperature limit.
1
70
10
°C/°F
10
do
type of deFrost: compressor OFF (not programmable)
-
-
-
-
11
dr
dripping time. After the defrost, the compressor remains OFF according to dripping time.
0
10
0
min
12
td
during defrost the indication dFis displayed,
with 0 = the room’s temperature is displayed during defrost.
0
99
20
min
13
AJ
zero adjustment of the sensor
-9
+10
0
°C/°F
14
tS
refresh delay of temperature indication at display.
0
20
0
sec
15
FC
switch °C/°F (0=°C, 1=°F) ATTENTION: changes between °C/°F do not apply on SPo
0
1
0
°C/°F
16
Br
baud rate (9600mbps)
-
-
-
-
17
tr
time response of the device to the CAMIN network
5
100
20
msec
18
FF
operation mode of relay ON-OFF (1=ON continuously, 0=ΟΝ when compressor is ON)
0
1
1
-
19
Ad
address of the device in the network.
0
250
2
-
ALARM TABLE
1
F1
cabinet sensor malfunction
The alarms are automatically deactivated when the cause of the alarm disappears.
Made in Greece.
ATTENTION according to safety standards, the device must be properly positioned and protected from any contact with electrical parts. All parts that provide protection must
be fastened in such a way that they cannot be removed without the use of tools. ATTENTION: disconnect the power supply of the device before proceeding to any kind of
maintenance. ATTENTION: do not place the device near heat sources, equipment containing strong magnets, in areas affected by direct sunlight or rain. ATTENTION: prevent
electrostatic discharges at the side slots of the device and sharp objects from been inserted. ATTENTION: separate the signal's cables from the power supply's cables to
prevent electromagnetic disorders. Signal cables must never be in the same pipe with the power supply cables. Use the device only as described in this document, not to
use itself as a security device. The device must be disposed of in accordance with local standards for the collection of electrical and electronic equipment. Read
and keep these instructions. The device is under two year's guarantee of good operation. The guarantee is valid only if the manual instructions have been applied. The
control and service of the device must be done by an authorized technician. The guarantee covers only the replacement or the service of the device.
.
preserves the right to adjust its products without further notice.
392 Mesogeion Avenue 153 41 Τ:+30 210 6533730 F:+30 210 6546331 info@kiour.com www.kiour.com