2. Stop engine, disconnect oil alarm connector, check the connector conduction, no conduct is normal.
3. Drain out the oil inside engine and check the conduction, conduct is normal.
4.4 Air cleaner
Inspection/Cleaning:
1) Loosen the cover screw and remove the maintenance cover.
2) Disengage the locking tab by pushing it, and remove the air cleaner cover.
3) Remove the element from the air cleaner case.
4) Clean the element in warm soapy water, rinse and allow to dry thoroughly and allow to dry.
5) Dip the element in clean engine oil and squeeze out all the excess oil.
6) Install the air cleaner element in the air cleaner case.
Clean the air cleaner rubber and the air cleaner case if necessary. Be sure that the air cleaner cover
seals are set securely.
7) Install the air cleaner cover. Be sure that the air cleaner cover seals are set securely.
8 Install the maintenance cover securely.
21
© 2011 Kipor Power Systems, Inc.

Other manuals for Kipor IG1000