6.5 Inspection
Float height
Place the carburetor as the picture shows, measure the float height between float and carburetor block.
Height 0.0047 in (12mm)
Replace the carburetor if the float height is not the right size.
Stepping motor
Measure the resistance of stepping motor lead-out wire.
Standard resistance
Between 1and 345~55
Between 2 and 445~55
Replace the stepping motor if the resistance excesses the above range.