10. Alternator/Trigger
10.1 Alternator
Disassembly/Reassembly
10.2 Inspection
(1) Ignition winding
Measure the resistance between the green terminal and yellow/green terminal.
Resistance 0.50-0.70
(2) Outer charging winding
Measure the resistance between the two blue terminals.
Resistance 0.12-0.15
(3) Sub winding
Measure the resistance between the two sub winding terminals.
Resistance White-white 0.25~0.35
(4) Main winding
Measure the resistance among the terminals of the main winding.
Resistance Black-black-black 2.0~3.0