30
6.
CONTROL PANEL, CHARGING ADJUSTOR, TIMING RELAY, IGNITION CONTROL
MODULE and INVERTER UNIT
6.1 Disassembly and assembly
Control panel
Timing relay
Ignition control module
Module fixing plate 2
Inverter unit
Charging regulator Module fixing plate1
6.2 Inspection
a. Control panel
AC Receptacle
Check for evidence of burning or contact damage. Replace if either condition exists.
DC Receptacle
Connect both terminals of the receptacle with a jumper wire and check if the receptacle is conductive
with two meter leads inserted into the panel; if not conductive, press the “Reset” button on the receptacle
panel and measure it again. If there is still no continuity, replace the DC receptacle.
Smart Throttle Switch
The switch is conductive when “ON” and not conductive when “OFF”.
Ignition Module
Remove the 10P connector from the module and connect one meter lead to the cover and the other lead
to the 10P connector and measure resistance.