EasyManua.ls Logo

Kipor KGE2500X - Pre-Operation Checks; Engine Oil Level Check

Kipor KGE2500X
25 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3. PRE-OPERATION CHECK
Be sure to check the generator is on a level and dry surface with the engine stopped.
STEP 1
. Check the engine oil level.
Using a non-detergent oil or 2-stroke engine oil could shorten the engine's service life.
It is recommended to use SAE 10W-30 Grade engine oil.
Only use a high-detergent, premium quality 4-stroke engine oil, certified to meet or exceed U.S.
automobile manufacturer's requirements for API Service Classification SG/SF.
To Check Oil Level
Remove the oil filler dipstick, and wipe the dipstick with a clean rag.
Insert the oil filler dipstick into the filler hole without rotating it.
If the oil level is below or at the lower end of the dipstick, refill with the recommended oil up to the
upper level mark. Tighten the oil filler dipstick.
Oil Capacity:
KGE2500X 0.6Lt
KGE4000X 1.1Lt
KGE6500X/E 1.1Lt
6