The air quality index label is designed to be permanently affixed to the generator and removal
should not be attempted.
Maintenance Schedule
REGULAR SERVICE PERIOD(1)
ITEM
Perform at every indicated month
or operating hour interval, which-
ever comes first.
EACH
USE
FIRST
MONTH
OR
20HRS
EVERY 3
MONTHS
OR
50HRS
EVERY 6
MONTHS
OR
100 HRS
EVERY
YEAR
OR
200 HRS
Check level
Engine oil
Change
Check
Air cleaner
Clean
○(1)
Clean-adjust
Spark plug
Replace
Combustion chamber
Clean
Every 300Hrs. (2)
Valve clearance
Clean-adjust
(2)
Fuel tank and filter
Clean
(2)
Fuel lines
Check
Every 2 years (Replace if necessary) (2)
NOTE: (1) Service more frequently when used in dusty areas.
(2) These items should be serviced by your servicing dealer unless you have the proper
tools and are mechanically proficient. Refer to the shop manual for service
procedures.
(3) For commercial use, log hours of operation to determine proper maintenance
intervals.