YES
NO
Appliance does not operate:
Is the output indicator light ON?
YES NO
YES
NO
Is the the overload
indicator light ON?
Take the generator to an
authorized dealer.
NO
Take the generator to an
authorized dealer.
Check the electrical appli-
ance or equipment for any
defects.
YES
Replace the electrical
appliance or equipment
Take the electrical appli-
ance or equipment to an
electrical shop for repair
No electricity at the DC receptacle:
Is DC circuit protector on?
Turn the DC circuit protector on.
Take the generator to an
authorized dealer.
-24-
10. SPECIFICATIONS
DC output
DC voltage
Electric circuit breaker
Phase number
12V-8.3A
Without
Single
Model
IG6000/IG6000h/IGLB6000
Rated frequency (Hz)
Rated voltage (V)
Rated current (A)
Rated speed (rpm)
Rated output (kVA)
Max output (kVA)
50
230
24.0
3600
5.5
6.0
60
240
22.9
Engine
Model Type
KG390GE
Type
Displacement (Bore Stroke)
Compression ratio
Rated power [kW(hp)/(r/min))]
Rated rotation speed (rpm)
Ignition system
Spark plug
Starting system
Fuel
Fuel consumption (g /kW.h)
Lube oil
Single cylinder, 4 stroke, vertical, air-cooled, OHV, gasoline engine
38.9ml (88 64mm)
8.5:1
7.7/3600
3600
T. C. I
F6TRC
Electric starter
Automotive unleaded gasoline
274
SAE 10W30 (above CC grade)
Fuel tank capacity (L)
Continuous running time (hr) (at rated output)
Noise level(zero load~ full load) [dB(A)/7m]
22.0
7.5
62-64 *
Dry weight [kg(lbs)]
-25-
60
120
45.8
Overall dimension (L W H) [mm(in)]
*: The declared values shall consider uncertainties due to production variation and
measurement procedures.
IG6000: 90 (198) IG6000h: 95 (209) IGLB6000: 205 (451)
IG000: 803 495 624(31.61 19.49 24.57)
IG6000h: 1235 650 770(48.62 5.59 30.31)
: 1185 880 1550(46.65 34.65 61.02)IGLB6000