Item Rated Value
Nominal center frequency 450kHz
6dB band width ±3.0kHz or higher
50dB band width ±9.5kHz or lower
Pulse 2.0dB or lower
Insertion loss 6.0dB or lower
Guarantee attenuation 47.0dB or higher
Terminal impedance 1.5k
Table 4.8 Features of CF1 LTWC450F
Item Rated Value
Nominal center frequency 450kHz
6dB band width ±6.0kHz or higher
50dB band width ±12.5kHz or lower
Pulse 2.0dB or lower
Insertion loss 6.0dB or lower
Guarantee attenuation 47.0dB or higher
Terminal impedance 1.5k
Chapter 5 Mode Introduction
Mode Introduction
Mode Function How to enter
User Mode For normal use Power ON
Data
Programming
Mode
Used to read and write
frequency data and
other features to and
from the radio
Received commands
from PC. See below for
further information.
PC Test Mode
Tune the radio
parameters by PC
Received commands
from PC. See below for
further information.
PC
Mode
Firmware
Programming
Mode
Upgrade the radio
when new features are
released
Press and hold P3 for
over 2 seconds while
turning the radio power
ON, and received
commands from PC
Wired Clone Mode
Used to transfer
programming data
from one radio to
another
Press and hold P1 for
over 2 seconds while
turning the radio power
ON
5.1 User Mode
You can enter User Mode (conventional communication mode)
by turning the radio power ON. Under this mode, users can use
the defined functions of the mobile radio.
5.2 Data Programming Mode
The radio has been set before leaving the factory. However,
due to different requirements of users, the radio’s operating
frequency, channels, CTCSS/DCS, scan, and other functional
parameters should be reprogrammed. Therefore, Kirisun has
specially designed a set of Chinese/English programming software
KSP8000 with friendly interface, convenient operation and
visualized display for setting functional parameters of the radio.
Steps for setting the functional parameters of the radio by PC
are as follows:
A. Install KSP8000 on the PC.
B. Connect the radio to the serial port of the PC with the
special programming cable (KSPL05). Refer to the figure below.
Figure 5.1
C. Turn the computer power ON.
D. Turn the radio power ON.
E. Run the KSP8000 programming software by double
clicking on its executive program.
F. Click “Program” in the main menu of KSP8000, and click
“Read from radio” in the pull-down menu to read parameters of
the radio to the computer; click “Write to radio” in the pull-down
menu to write parameters in the computer to the radio.
G. The following parameters can be set by using KSP8000
according to requirements of the user:
Radio Information:
Radio Type, Frequency Range, Serial Number, Embedded
Information, MCU Version, Hardware Version, etc.
Radio Configuration:
(1) Key Assignment: P1, P2, P3,
and can be set as
long/short key and the hold time can be defined.
(2) Miscellaneous
1. Wired Clone
2. TOT (Time Out Timer)
3. TOT Reset Timer
4. TOT Pre-Alert
5. TOT Rekey time
6. Squelch Level selection
7. Beep Tone
8. Read Data Password
9. Write Data Password
(3) Scan
Scan Function on/off, Priority Channel, Revert Channel, Tx
Dwell Time, Dropout Delay Time, Lookback Time.
(4) Emergency settings
Channel Information:
(1) Rx Frequency and Tx Frequency (Step:
2.5KHz/5KHz/6.25KHz)