SERVICE MANUAL Removals and Installations
23JUL01
SM5766-1
Page
18 of 96
14 To remove the LAMP MODULE RECEPTACLE from the PREHEAT DUCT, compress the
2 TABS on the LAMP MODULE RECEPTACLE.
Installation for the LAMP MODULE RECEPTACLE
Warning
Dangerous Voltage
1 Disconnect the main power.
2 Do the removal for the LAMP MODULE RECEPTACLE in reverse order.
A091_4013HA
SCREW (not shown)
LIGHT
BAFFLE
SCREW (2)
LOWER
A091_4013HCA
ASSEMBLY
COVER
BLOWER
SCREW (2)
RECEPTACLE
MODULE
LAMP
DUCT
PRE-HEAT