6HFWLRQ
/XEULFDWLRQ6\VWHP
)LJXUH&OHDQLQJ,QVLGHRI2LO&RROHU
2LO6HQWU\
*HQHUDO
Some engines are equipped with an optional Oil
Sentry™ switch. This switch is designed to prevent
the engine from starting in a low oil or no oil
condition. The Oil Sentry™ may not shut down
a running engine before damage occurs. In some
applications this switch may activate a warning signal.
Read your equipment manuals for more information.
The pressure switch is designed to break contact as
the oil pressure increases above 3-5 psi, and make
contact as the oil pressure decreases below 3-5 psi.
)LJXUH2LO)LOWHU/RFDWLRQ
5. Place a new replacement lter in a shallow pan
with the open end up. Pour new oil, of the proper
type, in through the threaded center hole. Stop
pouring when the oil reaches the boom of the
threads. Allow a minute or two for the oil to be
absorbed by the lter material.
6. Apply a thin lm of clean oil to the rubber gasket
on the new oil lter.
7. Install the new oil lter to the lter adapter or oil
cooler. Refer to instructions on the oil lter for
proper installation.
8. Fill the engine with the proper oil to the “FULL
or “F” mark on the dipstick. Always check the oil
level with the dipstick before adding more oil.
9. Reinstall the oil ll cap/dipstick.
10. Start the engine and check for oil leaks. Recheck
oil level before placing the engine into service.
Stop the engine, correct any leaks, and allow a
minute for the oil to drain down, then recheck the
level on the dipstick.
6HUYLFH2LO&RROHU
Some engines are equipped with an optional oil
cooler. Inspect and clean the oil cooler annually or
every 100 hours of operation (more frequently under
severe conditions). Oil cooler must be kept free of
debris.
2LO)LOWHU
)LJXUH&OHDQLQJ2XWVLGHRI2LO&RROHU
To service the oil cooler, clean the outside of ns with
a so brush. See Figure 6- 7. Remove the mounting
screws holding the cooler unit to the blower housing.
Tilt the cooler outward as shown in Figure 6-8.
Clean the inside of the cooler with a brush or with
compressed air. Aer cleaning, reinstall the oil cooler
to the blower housing with the mounting screws.
4. Remove the old lter and wipe o the lter
adapter with a clean cloth. See Figure 6-6.