Remove the Solenoid
Close the control stop valve (refer to the ″Control Stop Valve
Operation″ section).
NOTE: If the unit has not flushed since the stop valve was closed,
the inlet arm may still be pressurized. Use the manual flush button
to release pressure.
Use a 3/32″ hex head wrench to remove the setscrew from the
cap.
Remove the cap by lifting from the valve body.
Disconnect the DC sensor connector from the solenoid connector
by pulling the two connectors apart.
Temporarily store the cap and DC sensor assembly in a safe
place.
Use an adjustable wrench to remove the solenoid assembly from
the valve body by unscrewing counterclockwise until the solenoid
is free.
Valve Body
Diaphragm
Cap
DC Sensor
Connector
Solenoid
Assembly
Piston
Cover
Solenoid
Connector
Setscrew
O-Ring
Piston
Retaining Nut
Pin
Spring
Kohler Co. 11 1058866-5-D