Temperature Limit Adjustment
CAUTION: Risk of personal injury. Scalding may result if
the temperature limit is not properly set.
NOTE: The water temperature does not need to be adjusted if the
water temperature is below 105°F (41°C).
NOTE: Use a thermometer rated for 120°F (49°C) or greater.
NOTE: When using a tempered water supply, install the
vandal-resistant plug button.
Adjust the Water Temperature Limit Handle Installations
Turn on the water and adjust to full hot by turning the handle
toward the back of the faucet until it stops.
Determine the water temperature using a thermometer. If the
temperature exceeds 105°F (41°C), complete the following steps.
NOTICE: Do not rotate the handle when removing the screw.
Using the 2.5 mm hex wrench provided, remove and retain the
handle screw.
Remove and retain the handle with the spring washer.
Handle
Screw
Vandal-Resistant
Plug Button
Spring
Washer
Kohler Co. 5 1244026-5-A