EasyManua.ls Logo

Kohler K-2972 - Page 22

Kohler K-2972
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Adjust the Hot Temperature Limit (cont.)
Using a thermometer, check the temperature of the water.
Turn the valve stem clockwise until the water temperature
reaches 120°F (49°C).
Reinstall the spline adapter with the adapter tab positioned flush
with the hot temperature limit stop on the cartridge.
Using the volume control valve (not shown), turn off the water.
Hot Temperature
Limit Stop
Adapter Tab
Hot Temperature
Limit Stop
Adapter Tab
Spline Adapter
Valve Stem
1205551-2-C 22 Kohler Co.