P A R I S
16
1186051-W2-B
Handle Switch Troubleshooting Guide
Symptons Probable Causes Recommended Action
Handle LED is
lit when handle
is closed
Valve setscrew needs adjustment Refer to the ‘Handle LED Adjustment’
section
Handle does
not return to the
upright position
Valve setscrew needs adjustment Refer to the ‘Handle LED Adjustment’
section
Water does not
fully shut off
Valve setscrew needs adjustment Refer to the ‘Handle LED Adjustment’
section
Handle LED
does not
illuminate
when handle is
rotated open
Loose handle switch wire connection
Circuit board is not working
Check handle switch wore connection
to the circuit board
Replace the cover assembly
Sensor Troubleshooting Guide
Symptons Probable Causes Recommended Action
Intermittent
sensor
operation
Debris on the sensor lens
Sensor is detecting steam
Use mild soap and water to remove the
debis from the sensor lens
Rotate the spout away from the steam
Handle LED is
lit, but green
sensor LED is
not
Loose sensor wire connection
Debris on the sensor wire connector
Circuit board is not working
Check sensor wire connection to the
curcuit board
At the circuit board, gently disconnect,
clean, and reconnect the sensor wire
connector
Replace the cover assembly
Yellow sensor
LED does not
illuminate with
an object in
front of it
Object is clear or colour is
undetectable by the sensor
Debris on the wire sensor connector
Test the sensor wire using your hand
At the circuit board, gently disconnect,
clean, and reconnect the sensor wire
connector