Solenoid Troubleshooting Guide
Symptons Probable Causes Recommended Action
Water leaking
from the valve
Hose connections not secure
Internal leak
Turn off the main power and water
supply. Check all the connections
Replace the solenoid valve assembly
No audible
‘Click’ when
solenoid is
activated
Loose solenoid wire connection
Solenoid valve is not functioning
Check solenoid wire connection to the
circuit board
Replace the solenoid valve assembly
Guide de dépannage du robinet
Symptômes Causes probables Action recommandée
Pas de débit
d’eau
Les vannes d’arrêt sont fermées
La poignée est en position fermée
Le tuyau d’alimentation d’eau chaude
et/ou d’eau froide est plié
Le tuyau de vidange est plié
La poignée LED n’est pas allumée
Le capteur LED n’est pas allumé
Un ou plusieurs écrans sont bloqués
Assurez-vous que les vannes d’arrêt
soient ouvertes
Tournez le bouton en position ouverte
Assurez-vous que les tuyaux
d’alimentation ne sont pas pliés
Assurez-vous que l’électrovanne soit
située entre 178 et 203 mm de la base
du robinet
Veuillez vous reporter au “Tableau de
dépannage de l’interrupteur”
Veuillez vous reporter au “Tableau de
dépannage du capteur”
Veuillez vous reporter au “Nettoyage
des écrans”
Mauvais modèle
de douche
Le diffuseur de la douche est bouché
d’y ôter d’éventuels débris
La carte du
circuit LED n’est
pas allumée
Pas d’alimentation sur la carte du
circuit
Le cordon d’alimentation est branché
sur une commutation de sortie
l’alimentation à la carte du circuit
Branchez le cordon d’alimentation sur
une ligne non commutée
100 - 240 V AC. Assurez-vous que la
carte du circuit LED s’allume