4. Install the Finished Ceiling
Install the water-resistant wall board.
Cut out a 9 (229 mm) to 9-1/4 (235 mm) square at the desired
installation location.
Install the finished wall material.
5. Install the Pipe Nipple
Remove the nipples.
NOTE: The minimum distance between the face of the tees/elbows
and the surface of the finished ceiling should be 2-1/4 (57 mm).
The measurement for typical installations is 2-3/4 (70 mm).
Measure the distance from the face of the tees/elbows to the
surface of the finished ceiling. Make any adjustments as needed.
If your measurement is 2-1/4 (57 mm): Use close pipe nipples.
If your measurement is 2-3/4 (70 mm): Use 1-1/2 pipe nipples.
Thread the nipple into the tee/elbow and hand tighten.
9"
(229 mm) -
9-1/4"
(235 mm)
Cutout
Finished Ceiling
Tee
Tee
Nipple
Cutout
Finished
Ceiling
2-1/4"
(57 mm)
Min
9" (229 mm) -
9-1/4" (235 mm)
9"
(229 mm) -
9-1/4"
(235 mm)