TP-6836 4/1432 Section 4 Communication and Accessory Connections
4.3.2 Input/Output (I/O) Modules
Two types of input/output modules are available. The
standard I/O Module has two inputs and six outputs.
The high-power I/O module has two inputs and three
outputs. See Figure 4-10 through Figure 4-13 for I/O
module illustrations and specifications.
1. Input LEDs 7 and 8 for inputs 1 and 2
2. Input connector (see Figure 4-14)
3. Output connector
4. Output LEDs 1--6
1
GM41093
2
3
4
Figure 4-10 Standard Input/Output Module
Inputs
Available Inputs 2
Input Definition Contact Closure
Current 5mAMax
Connection Type Terminal Strip
Wire Size #14-24 AWG
Max Distance 700 feet
Outputs
Outputs Available 6
Contact Type Form C (SPDT)
Contact Voltage Rating
2A@30VDC
500 mA @ 125 VAC
Connection Type Terminal Strip
Wire Size #14-24 AWG
Figure 4-11 Standard I/O Module Specifications
1. Input LEDs 1 and 2
2. Input connector (see Figure 4-14)
3. Output connector
4. Output LEDs 3--5 for outputs 1, 2, and 3
2
GM42186
1
3
4
Figure 4-12 High-Power Input/Output Module
Inputs
Available Inputs 2
Input Definition Contact Closure
Current 5mAMax
Connection Type Terminal Strip
Wire Size #14-24 AWG
Max Distance 700 feet
Outputs
Outputs Available 3
Contact Type Form C (SPDT)
Contact Voltage Rating
12 A @ 24 VDC
12 A @ 250 VAC
10 A @ 277 VAC
2 A @ 480 VAC
Connection Type Terminal Strip
Wire Size #14-24 AWG
Environmental Specifications
Temperature -- 4 0 Cto85C(--40F to 185F)
Humidity 35% to 85% noncondensing
Figure 4-13 High-Power I/O Module Specifications