INSTALLATION GUIDE PRODUCT INFOMATION
SKU 5525T -NA 5526T -NA 5529T-NA 5531T-NA
Descri ption Steam
Genera tor
Steam
Genera tor
Steam
Genera tor
Steam
Genera tor
Power Rat ing 5KW 7KW 9KW 10KW
(He ight: 2.4M )
Steam Room Size 1.2M
2
2M
2
3M
2
3.7M
2
Maximum Volume Rat ing 3M
3
5M
3
7M
3
9M
3
Steam T empera ture
Adjustment
30°C (90°F) ~ 52°C (125°F)
Recom mended Operating
Time
10-20 min s
Electrical Ra ting AC 208 -240V, 5 0/60H Z
Dim ensions
(Wx HxD)
448 156 318 (m m)
Weight 11.9K G
Generator & Drain PanUser Interface Steam Head
The user interface must be installed inside the shower room and be at least 1500 mm
above the shower floor. It is not rec ommended to be insta lled vertically above the
steam head.
The steam pipe should not extend more than 7600mm between steam generator and
steam head.
The steam head is r ecommended to be installed at l east 152mm above the shower
flo or, and it i s not recommended to be installed on the s ame side as the attached
showe r seat.
Leave at least 300mm room on each side of steam generator to allow for heat
radiation.
1
1
2
3
4
2
3
4
x x