SEN00459-01 40 Troubleshooting
20 114E-3 Series
E-11 Code [155/CA155] Charge Air Press. High Speed Derate 1
Error code Failure code
Trouble Derating of speed by abnormally high charge temperature
155 CA155
Contents of
trouble
Temperature signal of boost pressure sensor and temperature sensor is above upper control limit.
Action of con-
troller
Limits output and continues operation.
Problem that
appears on
machine
Engine stops
Output drops.
Related infor-
mation
Possible causes
and standard
value in normal
state
Causes Standard value in normal state/Remarks on troubleshooting
1
Drop in cooling performance
of aftercooler
Inspect following directly.
Loose, broken fan belt
Lack of cooling air
Clogged aftercooler fin
2
Abnormally high tempera-
ture at turbocharger outlet
Inspect related parts directly.
3 Defective engine controller
If causes 1 and 2 are not detected, engine controller may be defec-
tive. (Since trouble is in system, troubleshooting cannot be carried
out.)