40 Troubleshooting SEN00459-01
114E-3 Series
3
Troubleshooting of electrical system (E-mode), Part 1 1
E-1 Code [111/CA111] Engine Controller Internal Failure 1
E-2 Code [115/CA115] Eng. Ne and Bkup Speed Sensor Error 1
Error code Failure code
Trouble Abnormality in engine Controller
111 CA111
Contents of
trouble
Abnormality occurred in memory of engine controller or power supply circuit.
Action of con-
troller
None in particular.
Problem that
appears on
machine
Engine stops during operations and engine cannot be started.
Related infor-
mation
Possible causes
and standard
value in normal
state
Causes Standard value in normal state/Remarks on troubleshooting
1 Defective engine controller Carry out troubleshooting for failure code [CA757].
Error code Failure code
Trouble Abnormality in engine Ne, Bkup speed sensor
115 CA115
Contents of
trouble
Abnormality occurred in signals of engine Ne speed sensor and engine Bkup speed sensor circuit.
Action of con-
troller
Problem that
appears on
machine
Engine stops
Engine does not start
Related infor-
mation
Method of reproducing failure code: Start engine.
Possible causes
and standard
value in normal
state
Causes Standard value in normal state/Remarks on troubleshooting
1
Defective connection of sen-
sor connector
Check Ne speed sensor and Bkup speed sensor directory for defec-
tive connection (wrong connection).