140-3 SERIES
12-209
TROUBLESHOOTING
ACTION TAKEN BY CONTROLLER AND CONDITION
OF MACHINE WHEN ERROR CODE IS DISPLAYED
Condition when normal Action by controller Problem that appears on machine
Sensor resistance value
Between SNE (1) and (2): 85 – 210
1. Limits output for operation
(when problem occurs independently)
2. Control of the system becomes impossi-
ble (when E-1C occurs at same time)
1. Reduces output (when problem occurs
independently)
2. Engine stops during operation
(when E-1C occurs at same time)
3. Engine cannot be started
(when E-1C occurs at same time)
Sensor resistance value
Between SG (1) and (2): 1.4 k – 3.5 k
1. Limits output for operation
(when problem occurs independently)
2. Control of the system becomes impossi-
ble (when E-1C occurs at same time)
1. Output is reduced (when problem
occurs independently)
2. Engine stops during operation
(when E-1b occurs at same time)
3. Engine cannot be started
(when E-1b occurs at same time)
Resistance in ground connection circuit
Between CN4 (female) and ground:
Max. 1
Resistance in ground cut-off circuit
Between CN4 (female) and ground:
Min. 1 M
1. Carries out operation under normal con-
trol.
1. Output is reduced
1. Stops fuel injection until engine speed
goes down to operating range.
1. Engine speed varies abnormally.
1. Limits fuel injection amount until temper-
ature goes down to operating range.
1. Output is reduced
Low-pressure switch resistance value
Between POL and ground
Engine stopped: Max. 1
Engine above 600 rpm: Min. 1 M
High-pressure switch resistance value
Between POH and ground
Engine stopped: Max. 1
Engine above 1,300 rpm: Min. 1 M
1. Limits output for operation 1. Runs at low idling.
Signal 2 voltage (between CN4 (11)
and (8))
Throttle below 0.446 V: Max. 1 V
Throttle above 0.446 V: 15 – 30 V
Signal 3 voltage (between CN4 (12)
and (8))
Throttle below 0.446 V: 15 – 30 V
Throttle above 0.446 V: Max. 1 V
1. Carries out operation under normal con-
trol.
1. Operates normally.
Sensor power source voltage
Between CN1 (4) and (11): 4.6 – 5.4 V
Sensor signal voltage
Between CN1 (6) and (11): 0.3 – 4.5 V
1. Actuated with throttle signal 100%
(when problem occurs independently
and simultaneously)
2. Actuated with throttle signal 0% (when
E-24 and E-36 occur at same time)
1. Fixed at high idling
(when problem occurs independently)
2. Fixed at low idling (when E-24 and E-36
occur at same time)
Sensor power source voltage
Between CN1 (4) and (11): 4.6 – 5.4 V
Sensor signal voltage
Between CN1 (6) and (11): 0.3 – 4.7 V
1. Actuated with throttle signal 100%
(when problem occurs independently
and simultaneously)
2. Actuated with throttle signal 0% (when
E-24 and E-36 occur at same time)
1. Fixed at high idling
(when problem occurs independently)
2. Fixed at low idling (when E-24 and E-36
occur at same time)
Sensor resistance value (water temper-
ature: 10 – 100ºC)
Between TWH (1) and (2): 90 k – 3.5 k
1. Carries out operation under normal
control.
1. Fixes water temperature signal output to
machine at 90ºC