PROGRAM PARAMETER MODE
2:Using the V C A decay keyboard tracking function,
Press 3 then 7* or use DATA ENTRY A to select the
function.
Use DATA EN TRY B to adjust the value.
F38 VCfl EG
Display for VCA decay keyboard tracking function.
I
......
...
i
FS i"'
UCR
DECfiV
KBDTRRCK-
.
20
Current value for this parameter
jJThe VCA envelope generator function.
The VCA EG lets you create an envelope {voltage
contour) that controls the V C A (voltage controlled
amplifiers)* there by determining how the volume
changes over time.
The VCA envelope is like that described for the VCF
EG* It has six parameters:
Attack time:
Controls how long it takes (after a key is played) for
the EG to reach its initial maximum voltage before the
decay time begins. The greater the value* the slower
the volume change*
Volume
Key played.
Decay time:
The time it takes from the end of the attack to the
break point level. The greater the value* the more
gradual the possible change in volume.
Volume
decay time is large.
/ If decay time is zero,
X . ___________________________________________________________________
Break point level.
Time