EasyManua.ls Logo

Kranzle 1122 TS T - Non-Return Valve Issues

Kranzle 1122 TS T
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
Possible cause no. 2: The non-return valve is soiled or defective.
Proceeding:
Switch off the HP cleaner and pull plug
from socket. Stop water supply. Unscrew
pump outlet.
Take out check ball and check for soiling
or damage.
Also check stainless steel seat of ball
inside the pump housing for soiling or
damage.
If sealing rings are defective replace
O-rings at once.
The pressure gauge shows full pressure although the trigger
gun with safety catch has been closed. The motor constantly swit-
ches on and off.
There is no guarantee if the pump is damaged by
defective O-rings due to air induction or lack of water
(cavitation).

Related product manuals