D
GB
F
NL
I
E
Alle in dieser Betriebsanleitung
aufgeführten Tätigkeiten dürfen
nur von autorisiertem Fach per-
sonal ausgeführt werden!
WARNUNG! Unsachgemäßer
Ein bau, Einstellung, Verän de rung,
Be die nung oder War tung kann
Ver letzungen oder Sachschäden
verursachen.
Anleitung vor dem Gebrauch lesen.
Dieses Gerät muss nach den
gelten den Vorschriften installiert
werden.
IFW 15 without transformer
has been replaced by the version
IFW 15 with transformer.
Important! This results in a
change in the type designation,
see “Testing”. If a flame detec-
tor IFW 15 without transformer
is replaced by a version IFW 15
with transformer, the wiring also
changes, see “Wiring”.
Testing
Previous type designation
IFW 15, without transformer
IFW 15-N, IFW 15-T,
IFW 15-NZ or IFW 15-TZ
IFW 15, with transformer
IFW 15T-N, IFW 15T-T,
IFW 15T-NZ or IFW 15T-TZ
N = 110/120 V mains voltage
T = 220/240 V mains voltage
Z = special variant
New type designation
IFW 15, with transformer
IFW 15-N, IFW 15-T,
IFW 15-NZ or IFW 15-TZ
N = 110/120 V mains voltage
T = 220/240 V mains voltage
Z = special variant
03250225 12.05 Fx/ivd 7.000
Austausch
Flammenwächter
IFW 15 ohne Trafo
gegen IFW 15 mit
Trafo
Umbauanleitung
Bitte lesen und aufbewahren
Zeichenerklärung
, 1, 2, 3... = Tätigkeit
= Hinweis
IFW 15 ohne Trafo
ist ersetzt durch die Ausführung
IFW 15 mit Trafo.
Prüfen
Bisherige Typenbezeichnung
IFW 15, ohne Trafo
IFW 15-N, IFW 15-T,
IFW 15-NZ oder IFW 15-TZ
IFW 15, mit Trafo
IFW 15T-N, IFW 15T-T,
IFW 15T-NZ oder IFW 15T-TZ
N = 110/120V Netzspannung
T = 220/240 V Netzspannung
Z = Sondervariante
Neue Typenbezeichnung
IFW 15, mit Trafo
IFW 15-N, IFW 15-T,
IFW 15-NZ oder IFW 15-TZ
N = 110/120V Netzspannung
T = 220/240 V Netzspannung
Z = Sondervariante
Achtung! Daraus ergibt sich eine
Änderung in der Typenbezeich-
nung, siehe „Prüfen“. Wird ein
Flammenwächter IFW 15 ohne
Trafo gegen IFW 15 mit Trafo ge-
tauscht, ändert sich die Verdrah-
tung, siehe „Verdrahten“.
D-49018 Osnabrück, Germany
220/240 VAC
50/60 HZ
-15/+60 °C
IP 40
IFW 15T-T
84359020 / B01.30 – 6438
D-49018 Osnabrück, Germany
220/240 VAC
50/60 HZ
-15/+60 °C
IP 40
IFW 15-T
84359020 / B01.30 – 7237
- 1 -
Elster GmbH
Postfach 2809
49018 Osnabrück
Edition 12.05
To replace the flame
detector IFW 15
without transformer
by the version IFW 15
with transformer
Conversion instructions
Please read and keep in a safe
place
Explanation of symbols
, 1, 2, 3 ... = Action
➔ = Instruction
D
GB
F
NL
I
E
WARNING! Incorrect installation,
adjustment, modification, opera-
tion or maintenance may cause
injury or material damage.
Read the instructions before use.
This unit must be installed in ac-
cordance with the regulations in
force.
All the work set out in these
operating instructions may on-
ly be completed by authorized
trained personnel!
Question and Answer IconNeed help?

Do you have a question about the krom schroeder IFW 15 and is the answer not in the manual?

Overview

This document provides conversion instructions for replacing the flame detector IFW 15 without a transformer with the IFW 15 version that includes a transformer. It is crucial to read and keep these instructions in a safe place.

Function Description:

The IFW 15 is a flame detector. This document specifically addresses the procedure for upgrading an existing IFW 15 unit (without a transformer) to a newer IFW 15 unit (with a transformer). This upgrade involves changes in the type designation and wiring.

Important Technical Specifications:

Previous Type Designation (IFW 15, without transformer):

  • Models: IFW 15-N, IFW 15-T, IFW 15-NZ, or IFW 15-TZ
  • IFW 15, with transformer (older designation):
    • Models: IFW 15T-N, IFW 15T-T, IFW 15T-NZ, or IFW 15T-TZ
    • N: 110/120 V mains voltage
    • T: 220/240 V mains voltage
    • Z: Special variant

New Type Designation (IFW 15, with transformer):

  • Models: IFW 15-N, IFW 15-T, IFW 15-NZ, or IFW 15-TZ
  • N: 110/120 V mains voltage
  • T: 220/240 V mains voltage
  • Z: Special variant

Example Device Specifications (from labels):

  • Model: IFW 15T-T
    • Part Number: 84359020 / B01.30-6438
    • Voltage: 220/240 VAC
    • Frequency: 50/60 HZ
    • Temperature Range: -15/+60 °C
    • Protection Class: IP 40
  • Model: IFW 15-T
    • Part Number: 84359020 / B01.30-7237
    • Voltage: 220/240 VAC
    • Frequency: 50/60 HZ
    • Temperature Range: -15/+60 °C
    • Protection Class: IP 40

Usage Features:

General Safety:

  • All tasks described in these operating instructions must be performed only by authorized and trained personnel.
  • Improper installation, adjustment, modification, operation, or maintenance can lead to injury or material damage.
  • The instructions must be read before use.
  • The unit must be installed in accordance with applicable regulations.

Conversion Process:

  • The IFW 15 without a transformer is replaced by the IFW 15 version with a transformer.
  • Important Note: This replacement results in a change in the type designation. Refer to the "Testing" section for details.
  • If an IFW 15 flame detector without a transformer is replaced by a version with a transformer, the wiring will also change. Refer to the "Wiring" section.

Wiring Instructions:

  • Ionization Control: Connect terminal 4 to the PE (protective earth) wire.
  • UV Control (for UV supervision): Connect terminal 3 on the UV sensor to terminal 4 on the flame detector.

Maintenance Features:

  • The document does not explicitly detail maintenance features but emphasizes that all work, including installation and adjustment, must be carried out by authorized personnel. This implies that any maintenance or troubleshooting should also adhere to this guideline.
  • For technical questions, users should contact their local branch office or agent. Contact information for Elster GmbH is provided, including a general service hotline and email.

Symbols Explanation:

  • ●, 1, 2, 3...: Indicates an action to be performed.
  • ←: Indicates an instruction or important information.

Manufacturer Information:

  • Manufacturer: Elster GmbH
  • Address (Germany): Postfach 2809, 49018 Osnabrück; Strotheweg 1, D-49504 Lotte (Büren)
  • Edition: 12.05
  • Contact:
    • Tel: +49 541 1214-0
    • Fax: +49 541 1214-370
    • Email: hts.lotte@honeywell.com
    • Website: www.kromschroeder.de
    • Central Service Hotline (worldwide): Tel +49 541 1214-365 or -499, Fax +49 541 1214-547

The manufacturer reserves the right to make technical modifications in the interest of progress.