Operator-friendly solenoid control unit
4.4.4 Test "Sensor cutters retract"
The "Cutters extend" sensor (1) is located on the cutter
unit on the right hand side of the machine.
As soon as the cutters on the cutter unit have been
swung out, the number after the word "Cutters retract"
on the display (10) must change to "1".
The distance between the sensor (1) and the solenoid (2)
must a = 2 mm.
XXL00003
4.4.5 Test "Sensor metering rollers"
The sensor (1) is on the left side of the machine on the
upper metering roller drive.
To test the sensor, turn the upper roller by hand. The
number after the words Metering roller in the display
changes to 1.
The distance between the sensor and the sprocket
wheel must be a = 1.5 mm.
4.4.6 Test "Sensor rear flap"
The sensor (1) is on the hinge point of the right lever
arm (3) for the rear flap.
To test the sensor, open the rear flap completely.
The value in the display after the words Rear flap
changes from 0 to 1.
The distance between the Reed sensor (1) and the
magnet (2) must be 5 mm.
a
KDW0634
1
KDW0631
3
1
2