EasyManua.ls Logo

Krone Big Pack 890 HS - Tightening Torques (Countersunk Screws)

Krone Big Pack 890 HS
324 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
227
Pos: 34.17 /Überschri ften/Überschri ften 2/A-E/Anzugsdre hmomente über Innensechska nt @ 45\mod_127710641576 5_78.doc @ 411230
11.5 Tightening Torques (Countersunk Screws)
Pos: 34.18 /BA/W artung/Drehmomente / Anzugsm omente/Drehmomente über Innensechskant @ 45\ mod_1277106232328_78. doc @ 411205
The tightening torque MA is stated in Nm
(unless otherwise indicated).
A = Thread size
(The stability class can be seen on the head of the
screw.)
A
Ø
5.6 8.8 10.9 12.9
MA (Nm)
M 4
2.5 3.5 4.1
M 5
4.7 7 8
M 6
8 12 15
M 8
20 29 35
M 10
23 39 58 67
M 12
34 68 100 116
M 14
108 160 188
M 16
168 248 292
M 20
340 488 568
A
BM 400 0234
NOTE
The table above applies only to countersunk screws with hexagonal socket heads and metric
threading that are tightened by the hexagonal socket head.
Pos: 34.19 /BA/W artung/Muttern und Schraube n (50h) anziehen @ 0\mod_11969 49864530_78.doc @ 15293
Note
Regularly check that nuts and bolts are tightly in place (approx. every 50 hours) and tighten
them if necessary.
Pos: 34.20 /BA/-----Seitenumbruch------ @ 0\mod_1196175311226_ 0.doc @ 4165