IV - 32
Comfort Control Unit
Diagnostics – Namur sensors
State:
• Alive (iron)
• Not alive (no iron)
• Broken cable
• Short circuit
Setting values:
The minimum and maximum setting value with the
sensor alive (metal in front of the sensor) are shown
in the upper part of the bar display.
The current setting value (actual value) is displayed
under the bar display.
The distance from the sensor to the metal must be
adjusted so that in the alive state, the bar lies in the
upper marked area.
Then check whether the bar is in the alive state in the
lower marked area.
No. Sensor icon Description
B1 Flywheel brake
B2 Upper blade bar
B3 Central lubrication
B4 Measuring
B5 Calibration
B6 Packer monitoring
B7 Packer feed
B8 Twine monitoring
B9 Needle connecting rod
B10 Knotter monitoring
B11 Bale chute
Possible sensors (depending on the design of the machine)
Nr. Sensor-Symbol Beschreibung
B12 Setting down bales
B14 Bale ejector
B20 Pickup
B30 Knotter monitor 1*
B31 Knotter monitor 2*
B32 Knotter monitor 3*
B33 Knotter monitor 4*
B34 Knotter monitor 5*
B35 Knotter monitor 6*
BPK40200
4-2
B4
state:
8,3V
7,3V
5,2V
2,4V
7,8V
1
B10
* Enumeration of sensors from left to right (in the
direction of travel)